About the Business
With over 30 years of experience in supplying our vast range of products throughout the UK we pride ourselves on the quality of the products which we supply for both residential and commercial use. Staying at the forefront of innovation and safety means that our 70,000 item product line is always increasing.
During our 30 years of business we have built up a reputation within the HVAC industry of only supplying the best products. Not only are we a manufacturer supplying our extensive range of products throughout the UK but we also carry out wide variety of work associated with the HVAC industry which ensures both commercial and residential premises follow legislations and law, this includes: ductwork installation and cleaning. Air conditioning and refrigeration unit installation, maintenance and repairs. As well as fire and smoke damper testing for certification.
Business Services
Ductwork Installation
Ductwork Installation
AJS have been providing high quality products associated with the HEVAC industry for 30 years, this goes hand-in-hand with our skilled and experienced ductwork installer & fitters who are all fully qualified and trained in health and safety procedures ensuring all ducting is installed to DW144 and fire ducts are installed to BW11 specification which means AJS can offer a full ductwork installation and modification service.
Air Conditioning & Refrigeration Installation, Maintenance & Repairs
Air Conditioning & Refrigeration Installation, Maintenance & Repairs
- Installation.
- Servicing/Maintenance.
- Repairs
Fire & Smoke Damper Testing Certification.
Fire & Smoke Damper Testing Certification.
AJS are able to provide full fire and smoke damper testing for already installed dampers within HVAC systems.
- Identify and locate each fire damper
- Retrofit access doors if any of these are inaccessible
- Carry out fire damper testing, cleaning and drop testing and reset each fire damper
- Provide accurate records of fire damper testing, cleaning and drop testing, including before and after photographs of cleaning
- Identify any problems and recommend remedial action
- Carry out remedial work where required
- Generally tested for Integrity (E), Insulation (I) (if required) and Reduced Leakage (S) (again, if required)
Duct Cleaning
- Changes to fire safety legislation which came into effect in April 2006 place the responsibility of fire risk assessments and associated works on the person/s deemed to be in control of all or part of the premises.
- All ductwork running through or part of a building should have at least annual surveys and maintenance work carried out to ensure that the system/s comply with the Guidance to Good Practice as outlined in the B&ES HVCA's TR19 publication.
- Failure to work to these standards will invalidate your buildings insurance policy in the event of a claim and may lead to HSE prosecution of the individual/s and company responsible.
- Detailed method statements and risk assessments, including relevant images site specific - no two premises are the same.
- Rapid response or structured timetable of working.
- All aspects tailored to clients needs with work taking place in downtime to minimise disruption.
- Cleaning works carried out by trained technicians using equipment and materials designed specifically for each application.
- All work carried out to B&ES HVCA's TR19 standards.
- Ensure compliance with fire safety regulations and buildings insurance requirements.
- Compliance certificates and comprehensive hygiene reports promptly provided.
Business Products
Flat Oval Access Doors.
Tabbed Access Door
Spiral Duct Access Door.
Blast Gate Dampers
Butterfly Back Draught Shutter.
Constant Volume Damper
Curtain Fire Dampers.
IRIS Dampers
Multi-Leaf Volume Control Dampers.
Non Return Dampers
Single/MFD Fire Dampers
Single Blade Volume Control Dampers.
Tri-Pro Dampers
T & Y Piece / Sections.
Access slip joints
Bends
Branches, Saddles & Shoes.
Cap Ends
Circular Duct Flange System
Couplers
Cowls
Flex
Reducers
Silencers
Spiral Tubing
AJS supply rigid spiral/circular tube for ducting in 48 different diameters, these range from 80mm all the way to 2000mm and produced in 3 meter lengths with a 1.6mm thickness. HVAC DW144 compliant, the rigid tubes are available in galavanised and stainless steel as well as aluminium to suit consumers needs and are suitable to be used in both commercial and industrial settings.
Split Rings
The suspension rings which are supplied by AJS are manufactured from galvanised steel and designed to support ducting. Made from two half circles which have additional flanges, which means the two halves can be bolted to form a full circle that ducting can be passed through and be safe in the knowledge that ventilation components such as flumes and ducting will be held in place securely - providing they are being attached to a solid fixture. The split rings are available in a wide range of diameters from 80mm to 1250mm, which means almost any circular component in a HVAC system will be held in place.
Suspension Ring
Channel brackets and plates
Channel End Caps
PVC black and white channel end caps are available in both 41x41mm and 41x21mm size variations and have been designed to fit into all styles of slotted channel/
Channel End Nuts
Slotted Channel
Slotted channel are a diverse component which are designed to support a range installation including full HVAC and air conditioning systems when attached to a variety of surfaces such as pre-existing steelwork or concrete inserts, walls, ceilings and floors which are supplied in a range of dimensions that comes in 3m, 5m and 6m lengths.
Diffusers
AJS supply a range of high quality ceiling diffusers that come in a range of shapes and sizes. Diffusers help to distribute both hot and cold air as well as extracting when connected to a HVAC system they are most often found in offices and replace a tile in a suspended ceilings, this is because they have been designed to use in open spaces and require a mounting height of between 2.6m and 4m. Diffusers are available in various different "ways" 1, 2, 3 and 4 as well as swirl and multicone option, the way is an idicator as to how many directions is distributed in.
Grilles & louvres.
Plenums or Grille Boxes
Providing the simplest and most effective way of connecting components such as grilles and diffuser to spiral/circular ducting with the use of an attached spigot. Grille boxes are manufactured in a variety of styles in order to attach the component to the boxes, this will be the entry and options are made for all of the available sides and combination of sides. There is also options for spigot plenum, this for when a component need to be connected to multiple ducts, these also come with an option for an additional flange.
Supply & Extract Valves
Location & Hours
Units 2 & 3, Bull Ring Trading Estate, Green Street
Write a Review
-
Email Address
-
Office
A J Services
-
Get Directions
Units 2 & 3, Bull Ring Trading Estate, Green Street, Birmingham, B12 0NB
-
Phone
-
Tollfree